Stainless steel bellows sealed stop valves GAV 66AF-T

A range of bellows sealed, in-line stop valves having flanged PN16, PN25 and PN40 connections for use on steam, gas, liquid, condensate and water systems.

Media Library

English
PDF - Installation instructions

Functional Safety IEC 61508 SIL 2 Level Electrode NRG 16-40, NRG 17-40, NRG 19-40, NRG 111-40 Level Electrode NRG 16-41, NRG 17-41, NRG 19-41, NRG 111-41 Level Electrode NRG 16-41.1, NRG 17-41.1, NRG 19-41.1, NRG 111-41.1 Level Switch NRS 1-40 Level Switch NRS 1-41 Level Switch NRS 1-40.1 Level Switch NRS 1-40.2 Temperature Transmitter TRV 5-40 with Temperature Sensor TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 or TRG 5-68

Level electrodes, temperature transmitters, control units and actuators (auxiliary contactors in safety circuit) are subsystems and together constitute a safety-related system that executes a safety function.

Media Library

English
PDF - Installation instructions

Non-Return Valve SRK 22A

The non-return valve SRK 22A ensures unidirectional flow in pipes by preventing a backflow of fluids. The valve disc is pressed against the seating surface in the event of reverse flow. As a result, the closed valve prevents a backflow of fluid. The guide ribs ensure correct alignment of the valve disc. When fitted with springs, the equipment can be installed in any plane. Different types of springs with different strengths are available. The force of the spring ensures that the valve only opens when the fluid flows in the right flow direction.

Media Library

English
PDF - Installation instructions

Universal converter URW 60

The URW 60 universal converter converts the analogue 4-20 mA signals from a connected level electrode into CAN bus telegrams. The data are transferred to an ISO 11898 CAN bus via the CANopen protocol. Function tests and failure diagnosis are performed using the URB 60 visual display and operating unit.

Media Library

English
PDF - Installation instructions

Non-Return Valve RK 16C, PN 40, DN 15-100 Hastelloy C

Application for particularly aggressive fluids, e. g. in the chemical industry.

Media Library

English
PDF - Data sheets

MPC1M, MPC2M and MPC2AM High Efficiency Compressed Air Filter/Regulators

The MPC_M range of (self-relieving) high efficiency oil removing filter/regulators provide very high quality compressed air, with accurate pressure control, for pneumatic actuators and general purpose systems.

Media Library

English
PDF - Data sheets

Kondensomat Duo BK 37 / BK 37 ASME, PN 63/CL 400, DN 15, 20, 25 BK 28 / BK 28 ASME, PN 100/CL 600, DN 15, 20, 25 BK 29 / BK 29 ASME, PN 160/CL 900, DN 15, 20, 25

Purgeur thermostatique avec régulateur Thermovit® (acier Duo), résistant à la corrosion et insensible aux coups de bélier. Filtre et sécurité anti-retour incorporés. Joint du corps sans amiante (graphite/CrNi). Montage dans n’importe quelle position. Le purgeur avec les réglages d’usine évacue le condensat pratiquement sans accumulation.

Media Library

French
PDF - Data sheets

Robinet de purge au démarrage AK 45

L’AK 45 évacue le condensat des installations vapeur au démarrage. L’AK 45 se ferme automatiquement lorsque la pression de fermeture réglée sur le robinet est atteinte. Après arrêt de l’installation ou dépassement de la pression de fermeture, le robinet s’ouvre et assure automatiquement la purge résiduelle.

Media Library

French
PDF - Installation instructions

Electric linear actuators for use with GCV control valves DN 15 to DN 100 AEL5 series

AEL5 series electric linear actuators are for use with LE, KE and JE two-port control valves, QL three-port valves and all bellows sealed options. Actuators will normally be supplied fitted to the control valve. When supplied separately, ensure the actuator selected is capable of giving the force necessary to close the two-port or three-port control valve against the expected differential pressure. See the appropriate product specific Technical Information Sheet for full details of the control valve.

Media Library

English
PDF - Installation instructions

Level electrode NRG 211-1

The level electrode NRG 211-1 is designed for measuring the water level in condensate lines. In conjunction with level switch NRS 2-4 the electrode can be used as max. limit switch with high level alarm.

Media Library

English
PDF - Installation instructions