AEL5 series electric linear actuators are for use with LE, KE and JE two-port control valves, QL three-port valves and all bellows sealed options. Actuators will normally be supplied fitted to the control valve. When supplied separately, ensure the actuator selected is capable of giving the force necessary to close the two-port or three-port control valve against the expected differential pressure. See the appropriate product specific Technical Information Sheet for full details of the control valve.
The level electrode NRG 211-1 is designed for measuring the water level in condensate lines. In conjunction with level switch NRS 2-4 the electrode can be used as max. limit switch with high level alarm.
The optimum components for every application
The level electrode NRG 16-50 S is used in conjunction with level switch NRS 1-50 (de-energizing delay: 15 seconds) as water-level limiter for steam boilers and (pressurized) hot-water installations on board of seagoing vessels, mobile offshore platforms or river boats. Water level limiters switch off the heating when the water level falls below the set minimum level (low water).
UKCA LRR1-52 LRR1-53 LRG16-4 LRG16-9 LRGT1x-x URB50 URB55
The SP500 smart valve positioner is a loop powered device that is able to drive linear and quarter turn pneumatic valves. A 4-20 mA input signal determines the valve set point. Precise control is maintained through valve position feedback that automatically varies the pneumatic output pressure to overcome the effects of stem friction and flow forces to maintain desired valve position.
The AEL5 series electric actuators are reversible having linear output.
The NRS 1-56 level switch measures using the conductivity principle and makes use of the electrical conductivity of the water to do this. The level switch is designed for different conductivities and for connection to four electrode rods in total.
The level switch NRS 1-53 in conjunction with level electrodes NRG 16-.. and ER 5. is used as limit switch, for instance as water level limiter in steam boilers and (pressurized) hot-water installations. The level switch detects and indicates two low water levels (MIN 1, MIN 2). The level switch can work with following level electrodes: NRG 10-52, NRG 16-52, NRG 16-4 and ER 5.-1.
Le régulateur de niveau NRR 2-61 peut être utilisé en association avec les électrodes de niveau NRG 26-60, NRG 26-61 comme régulateur de niveau d'eau et interrupteur MIN/MAX dans les installations de chaudière à vapeur et à eau surchauffée de même que dans les réservoirs de condensats et d'eau d’alimentation. Le régulateur de niveau NRR 2-61 peut être utilisé en association avec un convertisseur universel URW 60 * et combiné à une électrode de niveau externe (avec une sortie de courant 4-20 mA) également pour les applications ci-dessus.