Steam Trap MK 45-1, MK 45-2, MK 45A-1, MK 45A-2 PN 40 / Class 300 DN 15, 20, 25 (½", ¾", 1)

Thermostatic steam trap with corrosion-resistant thermostatic capsule. With Y-type strainer and integrated water hammer protection. Do not expose the control membrane capsule to superheat conditions above 5°C. Steam traps with standard capsule "N" discharge condensate with approx. 10 K below boiling temperature, traps with capsule "U" with an undercooling of approx. 30 K and traps with capsule "H" with approx. 5 K undercooling.

Media Library

English
PDF - Data sheets

GBV Ball Valve with Reduced Bore Firesafe API 607 DN 25 to DN 200 Flanged ASME 150 and ASME 300 M40Fi ISO

The M40Fi is a reduced bore ball valve, with a single piece body, having ISO mounting as standard. It is designed to be an isolating valve, which can be used with the majority of industrial fluids, not a control valve.

Media Library

English
PDF - Data sheets

Rapid-Action Intermittent Blowdown Valve PA 110, MPA 110 PN 160/250, CL 600/900/1500 DN 25

The following rapid-action intermittent blowdown valves are installed in pipes to discharge boiler blowdown water. - Rapid-action intermittent blowdown valve PA 110 (manually operated) - Rapid-action intermittent blowdown valve MPA 110 (automatically operated) The equipment must only be used within the allowable pressure and temperature limits and only if the chemical and corrosive influences on the equipment are taken into account.

Media Library

English
PDF - Data sheets

Cooling Water Control Valves Gestramat® Gestramat CW 41, CW 41/4 PN 16, DN 25 – 100 mm (1 – 4")

The cooling-water control valves type CW are direct-acting proportional controllers for installation in cooling water or brine return lines. They ensure that the cooling-water outlet temperature is maintained at a preset value, calculated for the process requirements. When using cooling-water control valves, higher temperatures are possible than with an uncontrolled process. As a result of the larger heat absorption by the cooling water or brine, cooling-agent and energy consumption are reduced.

Media Library

English
PDF - Data sheets

Indicateur de niveau NRS 1-53

Associé aux électrodes de niveau NRG 1.-.. et ER 5, l’indicateur de niveau NRS 1-53 est utilisé comme interrupteur MIN/MAX pour les installations de chaudière à vapeur et à eau surchauffée. L’indicateur de niveau signale que deux niveaux d’eau MIN (MIN 1, MIN 2) ont été atteints.

Media Library

French
PDF - Installation instructions

Clapet de retenue à intercaler entre deux brides PN 6/10/16/25/40, ASME Class 125/150/300 RK 76 DN 15-100, NPS ½-4

Les clapets de retenue des types RK servent à empêcher le reflux des fluides dans les conduites. Clapets de non-retour de construction plate, à intercaler entre deux brides, avec ressort pour une installation dans n’importe quelle position de montage. Sans ressort uniquement sur tuyauterie verticale, avec circulation du fluide de bas en haut. Centrage avec bague de centrage spéciale. Utilisation pour liquides, gaz et vapeurs. Veuillez respecter la classification selon la directive concernant les équipements sous pression.

Media Library

French
PDF - Data sheets

Steam Traps BK 37 / BK 37-ASME, PN 63/CL 400, DN 15, 20, 25 BK 28 / BK 28-ASME, PN 100/CL 600, DN 15, 20, 25 BK 29 / BK 29-ASME, PN 160/CL 900, DN 15, 20, 25

Thermostatic/thermodynamic steam trap with corrosion resistant Thermovit® regulator (bimetallic plates) able to withstand waterhammer. With internal strainer and integral non-return valve action. Asbestos-free body gasket (graphite/CrNi). Installation in any position. The default factory setting enables the steam trap to discharge condensate with virtually no banking-up.

Media Library

English
PDF - Data sheets

Vaposcope Sightglasses VK 14, DN 15, DN 20, DN 25, DN 40, DN 50, PN 16 VK 16, DN 15, DN 20, DN 25, DN 40, DN 50, PN 40

The GESTRA Vaposcope is a sight flow indicator specially designed for monitoring flow conditions in pipelines. If installed upstream of steam traps the Vaposcope can be used for checking the traps for steam loss or for banking-up of condensate.

Media Library

English
PDF - Data sheets

Continuous Blowdown Valve Reaktomat® BA 46 / BA 46-ASME, PN 40/CL 150/300, DN 15-DN 50 BA 47 / BA 47-ASME, PN 63/CL 600, DN 25, 40, 50 BAE 46... / BAE 46...-ASME, PN 40/CL 150/300, DN 15-DN 50 BAE 47... / BAE 47...-ASME, PN 63/CL 600, DN 25, 40, 50

Due to the continuous evaporation process in the steam boiler the density and hence the TDS (= Total Dissolved Solids) concentration of the boiler water is increased. The TDS level must remain within the limits specified by the boiler manufacturer and applicable guidelines. For this purpose a certain amount of boiler water (= boiler blowdown) is discharged continuously or periodically. The continuous blowdown valves BA... and BAE... feature specially designed and wear resistant nozzle stems that enter concentrically into a system of expansion chambers which are arranged one after the other, making the valve well suited for the continuous discharge of boiler blowdown at very high differential pressures. The continuous blowdown valves BA... and BAE... are suitable for operation in steam boiler plants according to TRD 604, EN 12952 and EN 12953.

Media Library

English
PDF - Data sheets

Condensate Drain Valve AK 45 PN 40, DN 15, 20, 25 (½", ¾", 1")

The AK 45 automatically drains condensate from steam systems during start-up, until the pressure in the system has reached the adjusted valve closing pressure. At shut-down or when the pressure falls below the closing pressure the valve opens and accumulated condensate is automatically drained away.

Media Library

English
PDF - Data sheets